Table 5 Comparison of reported complications with the reported method of frenotomy N = 190

From: Complications and misdiagnoses associated with infant frenotomy: results of a healthcare professional survey

Complication

Laser/Bovie/Electrosurgery

N (%)

Scissors/Scalpel

N (%)

Statistical significance

Chi square

Oral aversion

 Yes

38 (69)

17 (31)

p < 0.001*

 No

48 (36)

87 (64)

Scarring/retraction

 Yes

13 (54)

11 (46)

p = 0.348

 No

73 (44)

93 (56)

Parental report of pain

 Yes

18 (45)

22 (55)

p = 0.97

 No

68 (45)

82 (55)

Bleeding

 Yes

2 (10)

87 (90)

p = 0.001*

 No

84 (49)

87 (51)

Repeat procedure

 Considered/requested/performed

  Yes

10 (18)

46 (82)

p < 0.001

  No

76 (57)

58 (43)

  1. *Statistically significant